Comprehensive Corrosion Protection

We deliver end-to-end corrosion management for the global energy sector through

High-performance products for acidizing, pipelines, and refinery operations engineered for extreme conditions (180°C/350℉ | 28% HCl | 150,000ppm H₂S)

Premium quaternary ammonium compounds and imidazoline derivatives (thiourea/phosphorus-modified)

Solutions tailored to your brine composition, flow dynamics, and operational parameters within 72 hours

A series of comprehensive Corrosion Inhibitor Solutions for industries involved in oil & gas production, transportation as well as refinery operations.

CPAI-609

Acid fracturing, 60~90℃, 15~20% HCl and high concentration Mud Acid(HF + HCl)

CPAI-909

Acid fracturing, 60~90℃, 15~20% HCl and 10% HCl + 8%HBF4)

CPAI-409

Acid fracturing, 90~120℃, 15~20% HCl and high concentration Mud Acid(HF + HCl)

CPAI-014

Acid fracturing, 120~140℃, 15~20% HCl and high concentration Mud Acid(HF + HCl)

CPAI-016

Acid fracturing, around 160℃, 15~20% HCl and high concentration Mud Acid(HF + HCl)

CPR-902

Injection Water Corrosion Inhibitors, for the corrosive environment containing CO2, H2S and other acidic gas content not higher than 20% and mineralization not higher than 200,000mg/L brine, at < 100℃.

CPT-901

Applicable to the corrosion of oil gathering and transmission pipelines containing high partial pressure CO2, H2S and other acidic gases and higher mineralization brine, as well as to the control of high partial pressure CO2 on pipeline corrosion in the process of injecting CO2 into the oil field to drive oil.

CCO-2901

Suitable for the control of corrosion in the corrosive environment of high partial pressure CO2 and high mineralization brine in the process of CO2 oil drive in oilfields and the corrosion control of oilfield wastewater systems containing certain partial pressure CO2.

CIC-1901

Applicable to industrial boilers or chemical equipment used in the field of chemical cleaning 6 ~ 10% hydrochloric acid, citric acid, EDTA, hydroxyacetic acid or mixed acid acid acid cleaning process, the temperature below 100 ℃ can be applied.

Copper 8-Hydroxyquinoline

Unmatched Competitive Edge

Vertical Integration

Full control over imidazoline/quat synthesis ensures batch consistency and supply security

Extreme Performance

Validated protection in 180°C/28% HCl environments

Guaranteed Compatibility

Seamless integration with all major stimulation fluid systems

Rapid Adaptation

Reformulation for salinity, TAN, or flow challenges in days

Request Your Custom Corrosion Assessment

Blank Form (#4)